ALBI MAX is a clear, intumescent coating which will upgrade the Surface Spread of Flame performance on internal timber or timber-based boards. ALBI MAX is a two-part system comprising of ALBI MAX BASECOAT and ALBI OVERCOAT.
For use in dry, internal situations where a wall or ceiling lining in natural timber requires upgrading to achieve Class 1 Surface Spread of Flame in accordance with BS 476 : Part 7 or Class 0 in accordance with UK Building Regulations. Whilst ALBI MAX may be used on natural wood and wood veneer surfaces, it is not suitable for simulated wood surfaces or prefinished veneers.
When exposed to fire, ALBI MAX instantly reacts to form a dense insulative barrier which minimises heat transfer delaying ignition of the base material and impeding the spread of the fire.
| Product | Performance | Size | QTY per case |
|---|---|---|---|
| ALBI MAX BASECOAT | Class 1 or 0 | 5 Litre | 1 |
| ALBI MAX BASECOAT | Class 1 or 0 | 20 Litre | 1 |
| ALBI OVERCOAT | Protective | 1 Litre | 4 |
| ALBI OVERCOAT | Protective | 5 Litre | 1 |
ALBI OVERCOAT is a protective coating only. Available in matt,satin or gloss finish.
ALBI MAX should not change the colour of most timber surfaces. When a stained timber finish is required, only acid-fast penetrating wood stains may be used prior to the application of ALBI MAX. A single thin coat only of stain must be used and the stain must be allowed at least one week to dry to ensure dispersion of the solvent before the ALBI MAX system can be applied. The stained surface should be lightly sanded before application of ALBI MAX.
Since ALBI MAX BASECOAT is sensitive to moisture the most important consideration is to keep the timbers dry both during construction and service life. Application of the product in areas where high humidity or heavy wear is likely to occur e.g. swimming pools or kitchens may require modification to the standard specification. The ALBI MAX system must not be applied in areas where there is the likelihood of direct contact with water.
Timber coated in the ALBI MAX system should be allowed at least one week to dry out before being subject to high humidity. In the case of swimming pools, the pool should not be filled until at least two weeks after application has been completed and the central heating system is in full operation.
| Product | Manufacturer |
|---|---|
| Johnstones Woodworks Matt Finish Woodstain | Kalon Decorative Products |
| Ronseal Quick Drying Woodstain | Ronseal Ltd |
| Sadolin Classic | Akzo Nobel Woodcare Ltd |
| Dulux Trade Protective Woodsheen | ICI Paints |
| Sikkens Cetol HLS | Akzo Nobel Coatings Plc |